Feasibility of late gadolinium enhancement (LGE) in ischemic cardiomyopathy using 2D-multisegment LGE combined with artificial intelligence reconstruction deep learning noise reduction algorithm. Journal Article


Authors: Muscogiuri, G; Martini, C; Gatti, M; Dell'Aversana, S; Ricci, F; Guglielmo, M; Baggiano, A; Fusini, L; Bracciani, A; Scafuri, S; Andreini, D; Mushtaq, S; Conte, E; Gripari, P; Annoni, AD; Formenti, A; Mancini, ME; Bonfanti, L; Guaricci, AI; Janich, MA; Rabbat, MG; Pompilio, G; Pepi, M; Pontone, G
Article Title: Feasibility of late gadolinium enhancement (LGE) in ischemic cardiomyopathy using 2D-multisegment LGE combined with artificial intelligence reconstruction deep learning noise reduction algorithm.
Abstract: BACKGROUND: Despite the low spatial resolution of 2D-multisegment late gadolinium enhancement (2D-MSLGE) sequences, it may be useful in uncooperative patients instead of standard 2D single segmented inversion recovery gradient echo late gadolinium enhancement sequences (2D-SSLGE). The aim of the study is to assess the feasibility and comparison of 2D-MSLGE reconstructed with artificial intelligence reconstruction deep learning noise reduction (NR) algorithm compared to standard 2D-SSLGE in consecutive patients with ischemic cardiomyopathy (ICM). METHODS: Fifty-seven patients with known ICM referred for a clinically indicated CMR were enrolled in this study. 2D-MSLGE were reconstructed using a growing level of NR (0%,25%,50%,75%and 100%). Subjective image quality, signal to noise ratio (SNR) and contrast to noise ratio (CNR) were evaluated in each dataset and compared to standard 2D-SSLGE. Moreover, diagnostic accuracy, LGE mass and scan time were compared between 2D-MSLGE with NR and 2D-SSLGE. RESULTS: The application of NR reconstruction =50% to 2D-MSLGE provided better subjective image quality, CNR and SNR compared to 2D-SSLGE (p?0.01). The best compromise in terms of subjective and objective image quality was observed for values of 2D-MSLGE 75%, while no differences were found in terms of LGE quantification between 2D-MSLGE versus 2D-SSLGE, regardless the NR applied. The sensitivity, specificity, negative predictive value, positive predictive value and accuracy of 2D-MSLGE NR 75% were 87.77%,96.27%,96.13%,88.16% and 94.22%, respectively. Time of acquisition of 2D-MSLGE was significantly shorter compared to 2D-SSLGE (p?0.01). CONCLUSION: When compared to standard 2D-SSLGE, the application of NR reconstruction to 2D-MSLGE provides superior image quality with similar diagnostic accuracy.
Journal Title: International journal of cardiology
ISSN: 1874-1754; 0167-5273
Publisher: Unknown  
Date Published: 2021