Effect of Stent-Graft Active Fixation and Oversizing on Aortic Neck Dilation After Endovascular Aneurysm Exclusion For Infrarenal Aortic Aneurysm. Journal Article


Authors: Malach, L; Tehrani, N; Kolachina, S; Krawczyk, K; Wozniak, A; Soult, M; Aulivola, B; Bechara, CF
Article Title: Effect of Stent-Graft Active Fixation and Oversizing on Aortic Neck Dilation After Endovascular Aneurysm Exclusion For Infrarenal Aortic Aneurysm.
Abstract: INTRODUCTION: Aortic neck dilation post endovascular aneurysm repair (EVAR) has been implicated in the long-term development of endoleak and the subsequent re-intervention. Optimal endograft sizing is a vital aspect to successful repair. This study looked at percentage of graft oversizing as well as type of fixation on aortic neck dilation. METHODS: We retrospectively evaluated all EVARs completed at Loyola's University from 2006 to 2015 after IRB approval. Patients without follow-up scans within a year were excluded. We collected demographics, comorbidities, graft type, size, aortic neck diameter, maximum sac size diameters from the pre-operative and follow-up scans. We reviewed and collected data on 432 patients but analyzed 154. We measured the largest aortic diameter on axial images 1 cm above and 1 cm below the lowest renal artery. Change in supra and infrarenal aortic measurements were evaluated by calculating the mm difference from each scan compared to the pre-operative scan. Linear mixed effects models were used to estimate patients' mean differences over time. RESULTS: We compared three groups of neck fixation grafts. Those with active suprarenal fixation had a significant change in suprarenal aortic diameter at four-year follow-up (1.86 mm, CI:0.65-3.06), compared to those with active infrarenal (0.22 mm, CI: -0.67 to -1.11) or passive suprarenal fixation (1.52 mm, CI: -0.11 to -3.15) (Fig. 1). Those with active suprarenal fixation were the only ones to have significant increase in suprarenal aortic diameter (P = 0.0026). Degree of oversizing was also divided into three groups. Oversizing by 10% had less impact on the suprarenal aorta than >15% oversizing at 4 years (0.41 mm, CI: -0.31 to -1.14 vs. 3.26 mm, CI: 1.63-4.88, P 0.001) (Fig. 2). Oversizing had a more pronounced effect on the infrarenal aorta: 3.01 mm, CI: 2.18-3.83; 5.95 mm, CI: 3.26-8.64; and 5.05 mm, CI: 3.41-6.69 for 10%, 10-15%, and >15% oversizing at four years, respectively. CONCLUSION: Stent-grafts with active fixation below the renal arteries as well as oversizing by 10% seem to have the least effect on aortic neck dilation over time. These factors should be considered when performing EVARs, as aortic neck dilation could lead to endoleak and need for further intervention. Further research defining the optimal stent-graft type, self-expanding versus balloon expandable, type of fixation and degree of oversizing.
Journal Title: Annals of Vascular Surgery
ISSN: 1615-5947; 0890-5096
Publisher: Unknown  
Date Published: 2021